Hazard Communication WHMIS/GHS Chemical Inventory Audit
This procedure defines the systematic approach for auditing all chemical inventories against WHMIS 2015 (GHS) requirements — ensuring every container is labelled, every SDS is current, and every storage location is compliant with Canadian federal and provincial regulations.
To establish a standardized, auditable protocol for conducting a complete chemical inventory audit that ensures full compliance with the Hazardous Products Act and WHMIS 2015 (GHS) regulations. This SOP enables organizations to systematically verify that every hazardous chemical in the workplace has a current Safety Data Sheet (SDS), is labelled in accordance with GHS requirements, and is stored in a manner that minimizes risk to workers and the environment.
Regular audits reduce the likelihood of regulatory fines, improve emergency response capability, and form the backbone of a defensible hazard communication program under Part 5 of the Canada Occupational Health and Safety Regulations (COHSR) and provincial equivalents such as WorkSafeBC OHS Regulation Part 5.
This procedure applies to all operational areas, storage rooms, satellite accumulation zones, maintenance shops, laboratories, and point-of-use locations where hazardous chemicals — as defined by the Hazardous Products Regulation (HPR) — are received, stored, handled, or used. It covers:
- Bulk storage tanks, drums, totes, and portable containers
- Secondary (decanted) containers used for daily operations
- Laboratory chemicals, reagents, and analytical standards
- Cleaning agents, solvents, lubricants, and industrial process chemicals
- Waste hazardous materials awaiting disposal (satellite accumulation)
Excluded: Consumer products used in office areas that are exempt under WHMIS 2015 (e.g., office cleaning supplies in original packaging with no workplace exposure risk).
- Wear chemical-resistant gloves (nitrile or neoprene), safety goggles with splash shield, and a lab coat or chemical apron during all physical inventory walkthroughs. Upgrade to a full-face respirator with organic vapour cartridges if opening unknown containers is required.
- Ensure all storage areas are adequately ventilated. Do not enter confined chemical storage rooms without atmospheric monitoring (O₂, LEL, H₂S).
- Have a fully stocked chemical spill kit immediately accessible. If a leaking or damaged container is discovered, isolate the area, don appropriate PPE, and manage the spill per the site-specific spill response plan before proceeding.
- Verify chemical segregation during the audit — incompatible materials (e.g., oxidizers with flammables, acids with bases) must be physically separated. Never assume existing storage is correct.
- If the audit requires accessing locked storage rooms or moving palletized inventory, apply lockout/tagout to any powered material handling equipment before performing inspections or label scans.
- Master chemical inventory list (digital or printed from the management system)
- Current WHMIS 2015 Safety Data Sheets (SDS) for all chemicals on site — either physical binders or digital repository
- WHMIS 2015 GHS label templates and a thermal label printer or pre-printed GHS labels
- Barcode scanner, tablet, or mobile device with inventory management app
- Digital camera or phone camera for documenting container condition and labelling issues
- Chemical-resistant PPE (gloves, goggles, apron, respirator if required)
- Clipboard, audit log sheets, and permanent markers (oil-resistant, solvent-proof)
- Chemical spill kit (portable 20L pail with absorbents, neutralizers, and waste bags)
- Incompatible chemical segregation reference chart (GHS storage colour code guide)
- Torx or hex key set for opening locked storage cabinets if needed