Hearing Conservation Audiometric Testing And Earplug Fitting
Standardized procedure for performing audiometric threshold testing and fitting hearing protection (earplugs) to prevent noise-induced hearing loss in industrial environments where noise levels exceed 85 dBA over an 8-hour time-weighted average.
This standard operating procedure establishes a consistent, auditable method for conducting audiometric threshold testing and fitting hearing protection (earplugs) to prevent noise-induced hearing loss among industrial workers. The procedure ensures compliance with provincial occupational health and safety regulations, including WorkSafeBC Part 7 and CSA Z94.2-14 guidelines. By standardizing the testing protocol, earplug selection, and fit-verification process, this SOP aims to reduce the incidence of Standard Threshold Shifts (STS) and maintain a hearing conservation program that meets or exceeds regulatory requirements.
This SOP applies to all personnel working in areas where noise levels exceed 85 dBA over an 8-hour time-weighted average (TWA), including production, maintenance, and warehouse operators. It covers baseline audiograms for new hires, annual audiometric surveillance, exit audiograms upon employment termination, and earplug fit-testing for all personnel using hearing protection. This procedure is also applicable to any worker who self-reports hearing difficulty or who has been identified through incident investigation as having potential noise overexposure. The procedure is not intended to replace diagnostic audiology evaluations conducted by licensed audiologists for pathological conditions.
- Lockout/Tagout: Ensure all machinery is locked out and tagged out before entering the testing area to prevent acoustic interference and electrical hazards from adjacent equipment.
- Wear appropriate hearing protection (earplugs or earmuffs) during the entire procedure, including while assisting the employee and when outside the sound-attenuating booth.
- Use disposable hygiene covers on earphone cushions and probe tips for each worker. Replace covers between every test to prevent cross-contamination. Dispose of used covers in a lined waste receptacle.
- Verify audiometer calibration daily using a biological check (the operator's own hearing thresholds) or an acoustic coupler. Reject testing if calibration drifts beyond ±5 dB at any test frequency.
- Audiometer (diagnostic, Type 1 or Type 2 per ANSI S3.6–2018)
- Sound-attenuating booth or enclosure (ambient noise levels below 40 dBA)
- Otoscope with disposable specula
- Disposable hygiene covers for earphone cushions and probe tips
- Assorted earplug types: foam (e.g., 3M Classic, Howard Leight Max), premolded (e.g., E-A-R Ultrafit), and custom-molded options
- Earplug fit-testing system with real-ear attenuation measurement (e.g., 3M E-A-Rfit Dual-Ear, Honeywell VeriPRO)
- Training models and illustrated instruction cards for earplug insertion
- Audiometric record forms (paper or electronic)