Temperature Controller Calibration for Glue Pot

Standard procedure for calibrating the PID temperature controller on a glue pot to ensure adhesive viscosity consistency and prevent scorching.

Estimated Time
45 min
Difficulty
Advanced
Regulation
CSA Z432
Version
1.0
Free download — no sign‑up, no email.Take this SOP to your shop floor and make it yours.
Purpose

The purpose of this procedure is to outline the steps required to calibrate the temperature controller on a glue pot to ensure accurate temperature readings and consistent adhesive application. Proper calibration prevents equipment damage, reduces scrap, and maintains product quality.

Scope

This procedure applies to all glue pots equipped with PID temperature controllers (e.g., Nordson, ITW Dynatec) used in packaging or woodworking departments. It covers zero‑scale offset, proportional band adjustment, and verification using a calibrated reference thermometer.

Safety Precautions
  • LOTOLockout/tagout the glue pot electrical supply before accessing controller.
  • PPEWear heat‑resistant gloves and safety glasses when working near hot glue and electrical components.
Required Tools & Materials
  • Calibrated reference thermometer (NIST traceable, 0–200°C range)
  • Small flathead screwdriver
  • Multimeter for thermocouple resistance check
  • Temperature controller manual (for specific PID parameters)
  • LOTO kit
  • Heat‑resistant gloves
  • Safety glasses

Stop Chasing Maintenance Blindly

Track every calibration, pressure drop reading, and machine performance trend in one place. ServiceGrid logs your tasks automatically and alerts you before failure.

Try ServiceGrid →
Procedure: Step-by-Step
1 De‑energize and LOTO the glue pot electrical supply.
2 Access the temperature controller panel and remove the cover.
3 Connect the reference thermometer probe to the glue pot's temperature sensor location.
4 Re‑energize the system and allow the glue pot to reach setpoint (e.g., 150°C).
5 Compare controller reading to reference thermometer. If deviation exceeds ±2°C, adjust the offset parameter in the controller menu.
6 Repeat verification from a second setpoint (e.g., 180°C). Adjust proportional band if overshoot/undershoot is excessive.
7 Document calibration results on the PM log. Reinstall cover, remove LOTO, and return to service.