Commercial Vehicle Fire Extinguisher Monthly Inspection
This procedure outlines the monthly inspection process for fire extinguishers installed in commercial vehicles to ensure compliance with NFPA 10 and WorkSafeBC regulations. Proper inspection prevents fines, ensures equipment readiness, and enhances driver and asset safety.
The purpose of this monthly inspection is to verify that each commercial vehicle fire extinguisher is fully charged, mechanically sound, and ready for immediate use in an emergency. Early detection of tampering, corrosion, or pressure loss reduces fire risk and keeps the fleet compliant with provincial and national safety standards.
This SOP applies to all fire extinguishers mounted in fleet vehicles operated by the company, including dry chemical, CO₂, and halotron units with a rated capacity of 2-A:10-B:C or equivalent. It covers visual inspection, mechanical checks, weight verification (where applicable), and documentation requirements. Annual maintenance and hydrostatic testing are outside the scope of this monthly procedure.
- Ensure the vehicle is parked, engine off, and keys removed before removing the extinguisher from its bracket. No lockout/tagout required for non-powered equipment.
- Wear cut-resistant gloves and safety glasses when handling extinguishers. Some units may have sharp edges or residual powder around the nozzle.
- Never point the nozzle at yourself or others when examining the horn or hose. Do not discharge the extinguisher unless it is a scheduled training event.
- Fire extinguisher monthly inspection checklist (digital or paper)
- Personal protective equipment – gloves, safety glasses
- Flashlight (for inspecting hard-to-see areas)
- Smartphone or camera for photo documentation of gauge and tag
- Pen and permanent marker for tagging
- Weighing scale (for CO₂ or other weight-dependent extinguishers)