Industrial Maintenance & Reliability · SOP

Glue Pot Temperature Calibration & Purge Procedure: PUR & EVA

Comprehensive calibration and purge procedure for Nordson/Meltex-style glue pots and applicators. Ensures thermal accuracy, prevents adhesive degradation, and reduces nozzle plugging.

Estimated Time
45 min
Difficulty
Advanced
Regulation
ISO 9001:2024 / CSA Z432
Version
1.0
Free download — no sign‑up, no email.Take this SOP to your shop floor and make it yours.
Purpose

The purpose of this SOP is to establish a standardized methodology for calibrating the integrated resistance temperature detectors (RTDs) and thermocouples on PUR and EVA glue pots, and for executing a complete hot melt system purge. Accurate thermal control is critical to prevent charring (EVA) or cross-linking (PUR) which leads to costly nozzle and hose replacement.

Scope

This procedure applies to all PUR and EVA adhesive application equipment within the finishing department, including hand-held applicators and fully automated slot-die coating stations. It covers temperature verification against a NIST-traceable reference, PID controller offset adjustment, and the complete purge cycle using manufacturer-recommended flushing fluids.

Safety Precautions
  • BURNHOT SURFACE HAZARD: Glue pot and applicator hoses operate at 175–210°C. Allow system to cool to < 50°C before performing physical maintenance or purge fluid handling. Use high-temperature rated gloves (ASTM D120).
  • FUMETOXIC FUME EXPOSURE: PUR adhesive reacts with moisture and produces isocyanate vapors when heated. Ensure local exhaust ventilation (LEV) is operational and reading >0.5 m/s capture velocity at the source before beginning.
  • LOTOLOCKOUT/TAGOUT: Disconnect main electrical supply to the glue pot controller and pneumatically isolate the applicator before accessing thermocouple junctions or heater bands.
Required Tools & Materials
  • NIST-traceable surface/immersion thermometer (range: 0–300°C, resolution: 0.1°C)
  • PUR-grade purge fluid (e.g., DOP oil or manufacturer-specified glycol-ester blend)
  • EVA-compatible flushing compound (e.g., paraffin wax-based cleaner)
  • Torque wrench (for heater band bolts, spec: 8–12 N·m)
  • Isopropyl alcohol (99.9%) and lint-free wipes
  • High-temperature silicone grease (for thermocouple reinstallation)
  • ServiceGrid CMMS mobile device (to log calibration results and asset history)

Stop Chasing Maintenance Blindly

Track every calibration, pressure drop reading, and machine performance trend in one place. ServiceGrid logs your tasks automatically and alerts you before failure.

Try ServiceGrid →
Procedure: Step-by-Step
1 PREPARE SYSTEM: Ensure the glue pot has been idle for at least 30 minutes. Set temperature controller to standby (130°C for EVA, 110°C for PUR). Verify main adhesive supply is closed and applicator air pressure is bled down to 0 psi.
2 ACCESS THERMOCOUPLE SENSOR: Remove the protective cover plate on the glue pot manifold. Loosen the compression fitting securing the RTD or thermocouple. Carefully withdraw the sensor without bending the probe tip.
3 REFERENCE MEASUREMENT: Immerse the NIST-traceable probe into the adhesive bath (or a prepared glycerin bath of known temperature). Allow 5 minutes for thermal stabilization. Record the reference value (T_ref).
4 CONTROLLER VERIFICATION: Using the HMI, navigate to the 'Temperature Calibration' menu. Compare the controller reading (T_c) to T_ref. Calculate the offset: Offset = T_ref - T_c. If |Offset| > 3°C, proceed to Step 5. If < 3°C, note in ServiceGrid and skip to Step 6.
5 OFFSET ADJUSTMENT: Input the calculated offset into the controller calibration parameter. Perform a second verification cycle. Lock the calibration parameter with the supervisor passcode. Generate a calibration label and affix it to the controller face.
6 PURGE CYCLE INITIATION: Refill the glue pot with the appropriate purge fluid (PUR-grade DOP oil or EVA wax-based cleaner). Set temperature to 150°C. Activate the applicator in manual bleed mode. Cycle the purge fluid through the hoses and gun for 15 minutes or until the discharged fluid is clear.
7 FINAL PURGE & RESIDUAL REMOVAL: Reduce temperature to 100°C. Wipe down the glue pot surface and nozzle tips with isopropyl alcohol and lint-free wipes. Reinstall the thermocouple with a small dab of high-temperature silicone grease. Tighten compression fitting to 8 N·m.
8 RESTORE & DOCUMENT: Close all inspection panels. Restore pneumatic and electrical power. Load fresh adhesive and perform a test bead. Document the calibration offset, purge fluid lot number, and technician ID in the ServiceGrid asset log. Mark the PM work order as complete.